next up previous
Next: What you should have Up: Tasks Previous: In-lab Tasks:

Post-Lab Tasks:

  1. Compare the quantized measurements you observed for in-lab task 3 against your pre-lab predictions. Assess how well your ADC converts constant reference voltages.
  2. For the observations and measurements you made for in-lab task 4, plot the maximum observed voltage as a function of frequency. Use frequency domain concepts to explain your circuit's observed behavior. This task essentially asks you to evaluate the frequency response of your ADC.
  3. Use the data for in-lab task 5 to determine lowest refresh rate, above which flicker-fusion occurs.
  4. Demonstrate the functionality of your completed system to the TA. The TA will also check the completeness and correctness of your lab book, before signing off on the lab.



Michael Lemmon 2009-02-01