Next: What you should have
Up: Tasks
Previous: In-lab Tasks:
- Compare the quantized measurements you observed for
in-lab task 3 against your pre-lab predictions. Assess how
well your ADC converts constant reference voltages.
- For the observations and measurements you made for
in-lab task 4, plot the maximum observed voltage as a
function of frequency. Use frequency domain concepts to
explain your circuit's observed behavior. This task
essentially asks you to evaluate the frequency response of
your ADC.
- Use the data for in-lab task 5 to determine lowest
refresh rate, above which flicker-fusion occurs.
- Demonstrate the functionality of your completed
system to the TA. The TA will also check the completeness
and correctness of your lab book, before signing off on the
lab.
Michael Lemmon